47U rack cabinet houses, organizes and secures standard-width rack equipment in high-density server and IT networking areas.
Standard-Depth 47U Server Cabinet Accommodates 19 in. Rack EquipmentThis SmartRack® 47U rack enclosure is designed for network wiring closets, retail locations, classrooms, back offices and other areas with essential rack-mount IT equipment.
These 42U and 47U racks conform to the EIA-310-D industry standard for 19-inch, type A rack cabinets, and has outriggers (stabilizers) allowing for movement of a loaded rack. Features include: Thermal optimization supports high heat and power loads. A perforated front door allows air flow for a fan-free environment.
Can be set at 23 inch width or offset to one side on 800 mm models. Rails can be offset to either side by 50 mm on 800 mm wide racks. Removable, lockable side panels (2 locks per side on 1200 mm deep models) - on models with sides. 42U: 1865 mm, 47U: 2085 mm Note: PDU bracket allows the mounting of 2 rack PDUs side-by-side at the rear of the rack.
The lightning protection standard is an IEC standard and has therefore been incorporated in the standards of the CENE-LEC* member states whilst taking national circumstances into account. Country-specific standard designations and the associated national calculation values can be selected and displayed in the DEHN Risk Tool software.
To ensure a technically correct external lightning protection system, the protected volume must be properly dimen-sioned according to the height of the air-termination rod. With the DEHN Earthing Tool one can calculate the length of earth electrodes in compliance with IEC 62305-3.
The results of the risk analysis can be printed as a summary or detailed report in the rele-vant language. Specific protection measures must be taken to prevent lightning damage. Knowledge evolved from lightning re-search has also led to improvements in the calculation of the separation distance.
Knowledge evolved from lightning re-search has also led to improvements in the calculation of the separation distance. The current IEC 62305-3 standard requires that roof-mounted structures be located within the protected zone using air-termination rods or elevated air-termination systems (elevated ring conductor or spanned cables).
The cabinets covered by the technical specification have been designed to contain the hermetic lead-acid electric accumulator batteries.
Battery rooms shall be designed with an adequate exhaust system which provides for continuous ventilation of the battery room to prohibit the build-up of potentially explosive hydrogen gas. During normal operations, off gassing of the batteries is relatively small.
The rated capacity of a battery is based on an ambient temperature of 25°C (77°F). Any variation from this operating temperature can alter the performance of the battery. Battery capacity is diminished at low temperatures. Higher room temperatures will shorten the expected battery life.
Illuminance levels in the battery room shall be designed to meet IESNA Lighting Handbook recommendations with a minimum illumination level of 300 lux (30 fc). The lighting design shall consider the type of battery rack and the physical battery configuration to ensure that all points of connection, maintenance and testing are adequately illuminated.
Get technical specifications, product datasheets, and installation guides for our industrial cabinet solutions.