47U rack cabinet houses, organizes and secures standard-width rack equipment in high-density server and IT networking areas.
Standard-Depth 47U Server Cabinet Accommodates 19 in. Rack EquipmentThis SmartRack® 47U rack enclosure is designed for network wiring closets, retail locations, classrooms, back offices and other areas with essential rack-mount IT equipment.
These 42U and 47U racks conform to the EIA-310-D industry standard for 19-inch, type A rack cabinets, and has outriggers (stabilizers) allowing for movement of a loaded rack. Features include: Thermal optimization supports high heat and power loads. A perforated front door allows air flow for a fan-free environment.
Can be set at 23 inch width or offset to one side on 800 mm models. Rails can be offset to either side by 50 mm on 800 mm wide racks. Removable, lockable side panels (2 locks per side on 1200 mm deep models) - on models with sides. 42U: 1865 mm, 47U: 2085 mm Note: PDU bracket allows the mounting of 2 rack PDUs side-by-side at the rear of the rack.
The Type 4 telecom power outdoor cabinet is a new generation platform designed to meet customer needs, give configuration flexibility and supports a variety of applications. The cabinet is well suited for power, batteries and telecom equipment.
within the outdoor plant depends upon a cool, dry and secure environment for the electronics such as the DC power and Telecom equipment. The Type 4 Outdoor Power Cabinet more than accomplishes this with its Thermal Management that will keep sensitive electronics functioning in extreme environments.
Telcordia specifications GR-487 and GR-3108: The telecom industry has a long history of outdoor plant cabinets and has developed detailed specifications such as the Telcordia Requirements for Electronic Equipment Cabinets (GR-487) and the GR-3108, which specifies equipment testing criteria.
Although the most rugged types of telecom equipment can operate without heating and cooling, most outdoor telecom cabinets are designed to comply with the GR-3108-CORE Class 1 specification, which requires that the internal temperature of the cabinet is maintained between 41°F (5°C) and 104°F (40°C).
The lightning protection standard is an IEC standard and has therefore been incorporated in the standards of the CENE-LEC* member states whilst taking national circumstances into account. Country-specific standard designations and the associated national calculation values can be selected and displayed in the DEHN Risk Tool software.
To ensure a technically correct external lightning protection system, the protected volume must be properly dimen-sioned according to the height of the air-termination rod. With the DEHN Earthing Tool one can calculate the length of earth electrodes in compliance with IEC 62305-3.
The results of the risk analysis can be printed as a summary or detailed report in the rele-vant language. Specific protection measures must be taken to prevent lightning damage. Knowledge evolved from lightning re-search has also led to improvements in the calculation of the separation distance.
Knowledge evolved from lightning re-search has also led to improvements in the calculation of the separation distance. The current IEC 62305-3 standard requires that roof-mounted structures be located within the protected zone using air-termination rods or elevated air-termination systems (elevated ring conductor or spanned cables).
Get technical specifications, product datasheets, and installation guides for our industrial cabinet solutions.